AIR-1575 IR Camera is continuous zoom thermal imaging camera in LWIR band, adopts continuous zoom thermal imaging technology, both for a wide range of search, but also to identify distant targets. The product overcomes the shortcomings of the fixed focal length or dual field of view thermal imaging.
Spectral Band | 8-12 µm (LWIR) |
Array Type | Uncooled Microbolometer |
Detector | 640x480 |
Pitch Size | 17µm x 17µm |
NETD (detector; f/1, 300K) | < 50mK |
Autofocusing | Available |
Zoom time (NFOV to WFOV) | < 5.5 sec |
Focus Mechanism | Motorized |
WFOV - NFOV (Horizontal) | 43.4° - 8.2° (±%10) Motorized Continuous Zoom (Adjustable FOV's) |
Focal Length | 15mm - 75mm (±%10) |
F/# | 1.2 (±%10) |
Minimum Focusing Range | 7m (±%10) (WFOV) - 18m (±%10) (NFOV) |
Max. Dimensions | Ø76 mm x 150 mm |
Max. Weight | 400 gr |
Drive voltage | 6-12 VDC |
Current consumption | 0.15A average, 0.3A peak |
Communication interface | RS422, RS485, RS232 |
Drive voltage | Standard Version: 2.8 V to 5.5 V Extended Version: 6 V to 17 V |
Power consumption | Digital Output: < 0.7 W Analog Output: < 0.8 W |
Communication interface | RS232 |
Connector | Hirose 40 board to cable |
Digital Video Output | Parallel Video 1.8 V LVCMOS (8-bit data, vsync, hsync, pixclk), Ethernet (optional) |
Analog Video Output | PAL |
GPIO | 8 pins 1.8 V LVCMOS (Configurable wrt to customer requirements) |
External Trigger | Yes (controlled with 1 GPIO) |
Frame Rate | 25 Hz |
Time-to-image | < 2 sec (typically 1 sec) |
Digital Zoom | X1, X2, X3, X4, X8 |
Digital Zoom Continuous | From X1 to X8 with 0.02 steps |
Noise Cancelation | Adaptive Temporal and Spatial Noise Cancelation |
Detail Enhancement | Edge Aware Adaptive Digital Detail Enhancement |
Image Enhancement | Plateau-based Adaptive Histogram Equalization/Linear/Manual |
Color Palette | Up to 8 different palette |
Live Calibration | With Shutter (periodic or externally controllable) |
Operating Temperature | -32⁰ to +65⁰ |
Storage Temperature | -40⁰ to +70⁰ |